A.10.9 Input-Output for Real Types
Static Semantics
The following procedures are defined in the generic 
packages Float_IO, Fixed_IO, and Decimal_IO, which have to be instantiated 
for the appropriate floating point, ordinary fixed point, or decimal 
fixed point type respectively (indicated by Num in the specifications).
Values are output as 
decimal literals without low line characters. The format of each value 
output consists of a Fore field, a decimal point, an Aft field, and (if 
a nonzero Exp parameter is supplied) the letter E and an Exp field. The 
two possible formats thus correspond to:
Fore  .  Aft
and to:
Fore  .  Aft  E  Exp
without any spaces between these fields. The Fore 
field may include leading spaces, and a minus sign for negative values. 
The Aft field includes only decimal digits (possibly with trailing zeros). 
The Exp field includes the sign (plus or minus) and the exponent (possibly 
with leading zeros).
For floating point 
types, the default lengths of these fields are defined by the following 
variables that are declared in the generic package Float_IO:
Default_Fore : Field := 2;
Default_Aft  : Field := Num'Digits-1;
Default_Exp  : Field := 3;
For ordinary or decimal 
fixed point types, the default lengths of these fields are defined by 
the following variables that are declared in the generic packages Fixed_IO 
and Decimal_IO, respectively:
Default_Fore : Field := Num'Fore;
Default_Aft  : Field := Num'Aft;
Default_Exp  : Field := 0;
The following procedures 
are provided: 
procedure Get(File : in File_Type; Item : out Num; Width : in Field := 0);
procedure Get(Item : out Num; Width : in Field := 0);
If the value of 
the parameter Width is zero, skips any leading blanks, line terminators, 
or page terminators, then reads the longest possible sequence of characters 
matching the syntax of any of the following (see 
2.4): 
 
If a nonzero value of Width is supplied, then 
exactly Width characters are input, or the characters (possibly none) 
up to a line terminator, whichever comes first; any skipped leading blanks 
are included in the count.
Returns in the parameter Item the value of type 
Num that corresponds to the sequence input, preserving the sign (positive 
if none has been specified) of a zero value if Num is a floating point 
type and Num'Signed_Zeros is True.
The exception Data_Error 
is propagated if the sequence input does not have the required syntax 
or if the value obtained is not of the subtype Num.
procedure Put(File : in File_Type;
              Item : in Num;
              Fore : in Field := Default_Fore;
              Aft  : in Field := Default_Aft;
              Exp  : in Field := Default_Exp);
procedure Put(Item : in Num;
              Fore : in Field := Default_Fore;
              Aft  : in Field := Default_Aft;
              Exp  : in Field := Default_Exp);
Outputs the value of the parameter Item as a decimal 
literal with the format defined by Fore, Aft and Exp. If the value is 
negative, or if Num is a floating point type where Num'Signed_Zeros is 
True and the value is a negatively signed zero, then a minus sign is 
included in the integer part. If Exp has the value zero, then the integer 
part to be output has as many digits as are needed to represent the integer 
part of the value of Item, overriding Fore if necessary, or consists 
of the digit zero if the value of Item has no integer part.
If Exp has a value greater than zero, then the 
integer part to be output has a single digit, which is nonzero except 
for the value 0.0 of Item.
In both cases, however, if the integer part to 
be output has fewer than Fore characters, including any minus sign, then 
leading spaces are first output to make up the difference. The number 
of digits of the fractional part is given by Aft, or is one if Aft equals 
zero. The value is rounded; a value of exactly one half in the last place 
is rounded away from zero.
If Exp has the value 
zero, there is no exponent part. If Exp has a value greater than zero, 
then the exponent part to be output has as many digits as are needed 
to represent the exponent part of the value of Item (for which a single 
digit integer part is used), and includes an initial sign (plus or minus). 
If the exponent part to be output has fewer than Exp characters, including 
the sign, then leading zeros precede the digits, to make up the difference. 
For the value 0.0 of Item, the exponent has the value zero.
procedure Get(From : in String; Item : out Num; Last : out Positive);
Reads a real value from the beginning of the given 
string, following the same rule as the Get procedure that reads a real 
value from a file, but treating the end of the string as a file terminator. 
Returns, in the parameter Item, the value of type Num that corresponds 
to the sequence input. Returns in Last the index value such that From(Last) 
is the last character read.
The exception Data_Error 
is propagated if the sequence input does not have the required syntax, 
or if the value obtained is not of the subtype Num.
procedure Put(To   : out String;
              Item : in Num;
              Aft  : in Field := Default_Aft;
              Exp  : in Field := Default_Exp);
Outputs the value 
of the parameter Item to the given string, following the same rule as 
for output to a file, using a value for Fore such that the sequence of 
characters output exactly fills the string, including any leading spaces. 
Float_Text_IO is a 
library package that is a nongeneric equivalent to Text_IO.Float_IO for 
the predefined type Float: 
with Ada.Text_IO;
package Ada.Float_Text_IO 
is new Ada.Text_IO.Float_IO(Float);
 
For each predefined floating point type, a nongeneric 
equivalent to Text_IO.Float_IO is provided, with names such as Ada.Long_Float_Text_IO.
Implementation Permissions
An implementation may extend Get and Put for floating 
point types to support special values such as infinities and NaNs.
The implementation of Put need not produce an output 
value with greater accuracy than is supported for the base subtype. The 
additional accuracy, if any, of the value produced by Put when the number 
of requested digits in the integer and fractional parts exceeds the required 
accuracy is implementation defined. 
The nongeneric equivalent packages may, but need 
not, be actual instantiations of the generic package for the appropriate 
predefined type.
34  For an item with a positive value, if 
output to a string exactly fills the string without leading spaces, then 
output of the corresponding negative value will propagate Layout_Error.
35  The rules for the Value attribute (see 
3.5) and the rules for Get are based on the 
same set of formats. 
 
Examples
This paragraph 
was deleted.
package Real_IO is new Float_IO(Real); use Real_IO;
-- default format used at instantiation, Default_Exp = 3
X : Real := -123.4567;  --
  digits 8      (see 3.5.7) 
Put(X);  -- default format                            "–1.2345670E+02"
Put(X, Fore => 5, Aft => 3, Exp => 2);                -- "bbb–1.235E+2"
Put(X, 5, 3, 0);                                      -- "b–123.457"
Ada 2005 and 2012 Editions sponsored in part by Ada-Europe