A.18.24 The Generic Package Containers.Bounded_Ordered_Sets
The language-defined generic package Containers.Bounded_Ordered_Sets 
provides a private type Set and a set of operations. It provides the 
same operations as the package Containers.Ordered_Sets (see 
A.18.9), 
with the difference that the maximum storage is bounded.
 
Static Semantics
The declaration of 
the generic library package Containers.Bounded_Ordered_Sets has the same 
contents and semantics as Containers.Ordered_Sets except:
The type Set is declared 
with a discriminant that specifies the capacity (maximum number of elements) 
as follows: 
  type Set (Capacity : Count_Type) is tagged private;
The type Set needs finalization if and only if 
type Element_Type needs finalization.
If Insert (or Include) adds an element, a check 
is made that the capacity is not exceeded, and Capacity_Error is raised 
if this check fails.
In procedure Assign, if Source length is greater 
than Target capacity, then Capacity_Error is propagated.
The function Copy 
is replaced with: 
  function Copy (Source   : Set;
                 Capacity : Count_Type := 0) 
return Set;
 
Returns a set whose elements are initialized from 
the values in Source. If Capacity is 0, then the set capacity is the 
length of Source; if Capacity is equal to or greater than the length 
of Source, the set capacity is the specified value; otherwise, the operation 
propagates Capacity_Error. 
Bounded (Run-Time) Errors
 It is a bounded error to assign 
from a bounded set object while tampering with elements or cursors of 
that object is prohibited. Either Program_Error is raised by the assignment, 
execution proceeds with the target object prohibiting tampering with 
elements or cursors, or execution proceeds normally. 
 
Erroneous Execution
 When a bounded set object 
S is finalized, 
if tampering with cursors is prohibited for 
S other than due to 
an assignment from another set, then execution is erroneous. 
 
Implementation Requirements
 For each instance 
of Containers.Ordered_Sets and each instance of Containers.Bounded_Ordered_Sets, 
if the two instances meet the following conditions, then the output generated 
by the Set'Output or Set'Write subprograms of either instance shall be 
readable by the Set'Input or Set'Read of the other instance, respectively:
the Element_Type parameters of the two instances 
are statically matching subtypes of the same type; and
the output generated by Element_Type'Output or 
Element_Type'Write is readable by Element_Type'Input or Element_Type'Read, 
respectively (where Element_Type denotes the type of the two actual Element_Type 
parameters). 
Implementation Advice
 Bounded ordered set objects should be implemented 
without implicit pointers or dynamic allocation. 
 The implementation advice for procedure Move to 
minimize copying does not apply. 
Ada 2005 and 2012 Editions sponsored in part by Ada-Europe